TECHNICAL DATA

Heat aging test

time   unit AROSTOMER ARVAS
TF-A60NT-N1 T-A60NT-N1 VP-A60NT-N1
test temperature 100℃ 100℃ 100℃ 120℃
500hr Tensile strength retention % 121 143 108 104
Elongation retention % 95 78 74 90
Hardness change point 4 -1 2 ±0
1000hr Tensile strength retention % 130 148 93 112
Elongation retention % 70 70 93 80
Hardness change point 5 ±0 1 3

 

Chemicals&Oil resistance test

Appearance evaluation: ○: Not changed, △: Slightly colored, ▲: Colored, ●: Swelled or shrinkaged
Test condition : AROSTOMER 23℃×240hr、ARVAS 23℃×240hr

Chemicals AROSTOMER ARVAS
TF-A60NT-N1 VP-A60NT-N1
weight change(%) appearance weight change(%) appearance
Sulfuric acid 3%
30% -0.06 0.06
98% -0.06 4.01
Nitric acid 10% 1.02 0.36
60% 10.8 9.7
Hydrochloric acid 10% 0.34 0.06
36% 8.11 1.35
Acetic acid 10% 1.51
100% -2.88
Sodium hydroxide 10% -0.03 0.2
40% 0.03 0.25
Sodium chloride 10% -0.01 -0.17
Salad oil -3.63 -13
Chlorinated bleach 0.04 0.01
Neutral detergent -2.15 -4.24
Hair tonic 1.17 1.37
Ethanol 10%
50% 0.41 0.03
100% -11.7 -11.6
Methanol 10%
50% 0.24 ±0.00
100% -0.56 -4.07
IPA -19.6 -24.5
Ehylene glycol 0.03 -0.08
Toluene 24.5 102
Xylene 26.6 127
Carbon tetrachloride
Gasoline 10.3 128
Kerosene 130 134
ASTM No.1oil 9.06 12.6
IRM903oil 67.6 110
Silicon grease -5.92 -7.02

Weather resistance test

test machine:Sunshine Weather Meter
test condition:temperature 63℃、rain cycle 12min/1hr

time   unit AROSTOMER ARVAS
TF-A60NT-N1 TF-A60NT-B1 T-A60NT-N1 VP-A60NT-N1 VP-A60NT-B1
500hr Tensile strength retention % 101 106 108 92 76
Elongation retention % 96 101 104 38 57
Hardness change point 5 4 8 3 4
1000hr Tensile strength retention % 110 108 110 95 77
Elongation retention % 63 87 63 39 63
Hardness change point 4 3 4 1 2

Fusion strength

*Click on the series name to jump to the introduction page for each series. *

Our products base material
PP ABS PC PET PET-G 6Ny(PA) PBT POM AS
AROSTOMER TF series × × × × × ×
T series
ARVAS VP series × × × × × ×

◎:powerful fusion(Impossible to peel off by human force)
○:fusion(Difficult to peel off by human power, considerable force is required)
△:weak fusion(Can be peeled off by pulling strongly)
×:do not fuse(Easy to peel off with weak force)
– :No data
 
※By heating the base material to be fused, we recommend molding in a state where the fusion strength is improved.

Typical operation conditions

  AROSTOMER ARVAS
TF series VP
series
T series
Injection Underneeth the hopper(℃) 50 50
Cylinder(℃) 140~200 160~200
Nozzle(℃) 180~220 200~220
Mold(℃) 30~50 30~50
Cooling Time(Sec) 10~20 10~20
Extrusion Cylinder(℃) 140~200 150~200
Die(℃) 160~200 180~210
Drying

The above conditions are for reference only.

※The extrusion molding temperature for ”AR-FL series” is the set temperature for film molding.

Drying resins

Our elastomers essentially do not require pre-drying, but AR-BO series, AR-NF series, AR-EL series, and ESTERAR should be dried at 80-90°C for 3-4 hours.

Gates

The gate shown in Figure A may fail due to jetting. B- or C-type gate is recommended.

Molds

●Designing a mold can be essentially the as same as that of olefin resins. It may not be well released only by extrusion pins for its soft material and product shape. In this case, we recommend using a combination of air and a stripper plate.

●For gas release, secure 1/100 mm to 2/100 mm.

●Flow marks may be caused, so we recommend a stain finish or a grain finish for the product surface.

Molding machines

Our elastomers can be used to perform molding using an extruder or an injector for olefin resins or styrene resins. Special facilities are not required.

Note

– Each of the characteristic values in the data are typical measurement values, not guaranteed values.

– When considering use to members which contact oil, you must contact our sales representatives in advance to inquire of the use environment and conditions. Deformations or color modifications may occur to the molding items depending on the use environment and conditions.

– When considering use to members which are related to physical bodies such as medical and food use, you must contact our sales representatives in advance.We will not be liable for any accidents caused by use to the members related to your body such as members for medical use and for foods without our consent.

– For the use of our elastomers, please test and confirm safety, conformity, and intellectual property issues in advance.

Scroll to Top